30MIN | 60MIN | 90MIN | 120MIN | 240MIN | |
---|---|---|---|---|---|
100MM | Hi-Spec Fair Faced | XtraFire | XtraFire | XtraFire | XtraFire |
140MM | Hi-Spec Fair Faced | Ultra-Fire Fire Spec Faced Fire | Ultra-Fire Fire Spec Faced Fire | Ultra-Fire | Ultra-Fire |
190MM | Hi-Spec Fair Faced | Fire Spec Faced Fire | Fire Spec Faced Fire | Fire Spec Faced Fire | |
215MM | Hi-Spec Fair Faced | Ultra-Fire Fire Spec Faced Fire | Ultra-Fire Fire Spec Faced Fire | Ultra-Fire Fire Spec Faced Fire | Ultra-Fire |
Why you should buy Allen Concrete fire rated lintels
- XtraFire and Ultra-Fire lintels tested by Exova Warrington fire testing facility
- They meet the requirements of the Construction Products Regulation in relation to declarations of performance and CE Marking.
- They are manufactured, quality controlled and continually assessed to ensure compliance to BS EN ISO 9001:2015
- XtraFire Lintels use cement replacement technology, which uses less than 20% of the energy and produces less than 10% of the CO2 emissions compared to Portland cement production.
XtraFire fire-resistant concrete lintels
XtraFire is a single cast lintel which has been independently tested for fire resistance and load bearing capacity by Warrington Fire and Lucideon.
Fire Rating – The XFR6 lintels are fire rated up to R180 minutes for load-bearing and XFR9 lintels are fire rated up to R240 minutes for load bearing.
Finish – An ex steel mould finish similar to our current fairfaced product made from specialist wet cast concrete.
Selling Points | XtraFire | Ultra-Fire |
---|---|---|
Can be exposed to cyclic wetting/drying | Y | N |
Solid concrete 1 Part unit. No need for additional coatings | Y | N |
Shorter lead times | Y | N |
Can be used in aggressive environments | Y | N |
Increased durability over time | Y | N |
Can be fixed into on site | Y | N |
Smooth ex steel mould finish | Y | N |
More durable during stocking / storage | Y | N |
Can be cut on site. Unlike other methods of manufacture | Y | N |
Ultra-Fire range of concrete lintels
A range of lintels with an enhanced fire resistance. Due to the special coating applied, all of our lintels can achieve a 240 minute load bearing capability when subject to fire conditions.
These lintels have a slightly different texture to concrete but are smooth. They can also be left natural but we would advise the use of a waterproof sealant to reduce surface dusting.
Under no circumstances should the Ultra-Fire Range of Lintels be cut down in sizes due to stooled end bearings.
Fire-Spec Range
Naylor Fire-Spec collection is our ex-steel mould finish range of high performance units. They are available in 60, 90 and 120 minutes, dependant upon the section width.
Fair Faced Fire-Spec Range
Naylor Fair Faced Fire-Spec lintels are also available in a class C fair faced finish and again with a 60, 90 and 120 minute fire rating.